高级检索

本文对三维内微肋管内进口区段R134a过热蒸汽的凝结换热过程进行了实验研究。结果表明:微肋管内过热蒸汽过热度降低的速率明显高于光管,且主要受质量流率和管壁过冷度的影响。本文得到的过热蒸汽凝结换热计算式与实验的偏差在±15%以内。

An experimental investigation of R134a superheated vapor condensation in the entrance region of three-dimensional microfin tube is conducted. The decease rate of superheated vapor temperature in the 3-D microfin tube is larger than that in smooth tube. The obtained empirical correlation of superheated vapor condensation has ±15% deviation when compared with the experimental data.

参考文献

[1] R. L. Webb .Convective condensation of superheated vapor[J].Journal of heat transfer: Transactions of the ASME,1998(2):418-421.
[2] Lee C C;Teng Y J;Lu D C.An Investigation of Condensation Heat Transfer of Superheated R-22 Vapor in a Horizontal Tube[A].,1991:1051-1057.
[3] CHEN Qinghua;CUI Wenzhi;XIN Mingdao.Condensation in Horizontal Three-Dimensional Microfin Tube for Refrigerant R134a[A].,1999:115-119.
[4] 顾维藻.强化传热[M].北京:科学出版社,1990