为研究预加直流电压对油纸绝缘局部放电过程的影响特性,采用球-板电极模拟油纸绝缘系统中的稍不均匀电场,仿真计算出预加直流电压下球-板电极油纸绝缘系统的电势和场强分布,用脉冲电声法测试绝缘纸板去极化过程空间电荷时空变化特性与界面空间电荷衰减速率,并对试样进行交流局部放电试验,研究预加直流电压与局部放电起始电压之间的定量关系。结果表明:预加直流电压会在绝缘纸板界面产生残留空间电荷,升压过程中使局部放电起始电压和绝缘临界击穿电压均下降;降压过程中局部放电特性不受预加直流电压的影响,且局部放电熄灭电压与预加电压大小无关;随着预加直流电压的提高,每升高相同幅值的预加直流电压,交流局部放电起始电压降低的幅值有所减小。
To study the effect of pre-applied DC voltage on the partial discharge process of oil-paper insu-lation, we used ball-plate electrode to simulate the slightly non-uniform electric field in oil-paper insula-tion system. The distribution of voltage and electric field intensity of the oil-paper insulation system un-der pre-applied DC voltage was calculated through simulation. The spatial and temporal variation and de-cay rate of space charge of the pressboard during the depolarization process was tested by PEA(Pulsed Electro-acoustic) method. The AC partial discharge test was carried out, and the quantitative relationship between pre-applied DC voltage and partial discharge inception voltage was studied. The results show that the pre-applied DC voltage would leave residual space charge on the surface of the pressboard, which make the partial discharge inception voltage(PDIV) and critical breakdown voltage(CBV) decrease in the voltage process. While the pre-applied DC voltage almost has no effect on the voltage reduction process and the partial discharge extinction voltage (PDEV) is independent of the pre-applied voltage. With the increase of the pre-applied DC voltage, the decrease amplitude of AC partial discharge incep-tion voltage decrease.
参考文献
[1] | GB/T 18494.2-2007, 交流变压器第2部分:高压直流输电用换流变压器[S].,2007. |
[2] | 李博,程涣超,孙倩,李金忠,李光范,邓俊宇,樊炜,徐会雨.交直流电压分量对变压器油中典型模型击穿特性影响[J].电工技术学报,2011(02):34-38. |
[3] | 沙彦超,周远翔,孙清华,黄猛,金福宝,黄建文.直流电压分量对交直流叠加电压下油纸绝缘沿面闪络的影响[J].高电压技术,2013(06):1337-1343. |
[4] | Di Lorenzo del Casale M, Schifani R, Holboll J T . Partial Discharge Tests using CIGRE Method II[J].IEEE Transac-tions on Dielectrics and Electrical Insulation,2000,7(1):133-140.,2000. |
[5] | 廖瑞金,严家明,杨丽君,朱孟兆,孙才新.局部放电对油浸绝缘纸表面损伤特性研究[J].中国电机工程学报,2011(10):129-137. |
[6] | GB/T 7595-2008, 运行中变压器油质量[S].,2008. |
[7] | GB/T 7354-2003, 局部放电测量[S].,2003. |
[8] | 李晓辉,李岩,李冬雪,额尔和木巴亚尔.换流变压器阀侧绕组非线性各向异性直流电场分析[J].高压电器,2012(04):18-22. |
[9] | 周远翔,黄猛,陈维江,孙清华,王云杉,张灵.直流电场下油纸绝缘介质界面处的空间电荷特性[J].高电压技术,2011(10):2417-2423. |
[10] | Tang C, Chen G, Fu M, et al . Space Charge Behavior in Multi-layer Oil-paper Insulation under Different DC Voltag-es and Temperatures[J].IEEE Transactions on Dielectrics and Electrical Insulation,2010,17(3):775-784.,2010. |
[11] | 李晓华,吴广宁,边姗姗,彭倩.直流和交流电压下典型缺陷模型局部放电波形比较分析[J].绝缘材料,2008(01):53-56. |
[12] | 司文荣,李军浩,袁鹏,郭弘,罗勇芬,李彦明.直流下局部放电序列信号检测与特性分析[J].电工技术学报,2010(03):164-171. |
[13] | 王伟,薛阳,程养春,陈明,徐建峰,李成榕.变压器油纸绝缘沿面放电程度的诊断[J].高电压技术,2011(07):1713-1718. |
[14] | 周远翔,沙彦超,陈维江,卢理成,聂德鑫,伍志荣,邓建钢.变压器油与绝缘纸板电导特性研究[J].电网技术,2013(09):2527-2533. |
[15] | 周远翔,黄猛,陈维江,孙清华,沙彦超,张灵.直流电压下多层油纸绝缘介质的界面空间电荷特性[J].高电压技术,2013(06):1304-1311. |
[16] | 赵永贵 .混合电场下油纸绝缘系统击穿和沿面闪络特性的研究[D].哈尔滨理工大学,2011. |
[17] | 卢毅,周远翔,梁曦东,王宁华.直流复合绝缘子芯棒材料中空间电荷特性研究[J].绝缘材料,2007(02):44-47. |
[18] | Mizutani T . Space Charge Measurement Techniques and Space Charge in Polyethylene[J].IEEE Transactions on Dielectrics and Electrical Insulation,1994,1(5):923-933.,1994. |