制冷剂闪蒸瞬态喷雾冷却是皮肤激光手术中的重要辅助手段,既能够提高激光能量改善治疗效果,又可以保护表皮正常组织不受激光热损伤.针对制冷剂闪蒸瞬态喷雾冷却过程中所涉及的喷雾动力学和复杂沸腾相变传热等学术难点问题,本文建立了制冷剂闪蒸喷雾冷却实验台,对R134a制冷剂闪蒸喷雾冷却的喷雾特性和表面传热特性进行实验研究,得到了制冷剂闪蒸瞬态喷雾冷却特定喷雾条件下的喷雾特性和表面传热特性,以期为皮肤激光临床手术提供定量的指导.
参考文献
[1] | Chang,CJ;Anvari,B;Nelson,JS .Cryogen spray cooling for spatially selective photocoagulation of hemangiomas: a new methodology with preliminary clinical reports.[J].Plastic and Reconstructive Surgery,1998(2):459-463. |
[2] | Anvari B.;Milner TE.;Tang K.;Liaw LH.;Kalafus K.;Kimel S.;Nelson JS.;Tanenbaum BS. .SPATIALLY SELECTIVE PHOTOCOAGULATION OF BIOLOGICAL TISSUES - FEASIBILITY STUDY UTILIZING CRYOGEN SPRAY COOLING[J].Applied optics,1996(19):3314-3320. |
[3] | Aguilar G;Wang GX;Nelson JS .Dynamic behavior of cryogen spray cooling: effects of spurt duration and spray distance.[J].Lasers in surgery and medicine,2003(2):152-159. |
[4] | Aguilar G;Majaron B;Pope K;Svaasand LO;Lavernia EJ;Nelson JS .Influence of nozzle-to-skin distance in cryogen spray cooling for dermatologic laser surgery.[J].Lasers in surgery and medicine,2001(2):113-120. |
[5] | Guillermo Aguilar;Henry Vu;J Stuart Nelson .Influence of angle between the nozzle and skin surface on the heat flux and overall heat extraction during cryogen spray cooling[J].Physics in medicine and biology,2004(10):N147-N153. |
[6] | Boris Majaron;Lars O Svaasand;Guillermo Aguilar;J Stuart Nelson .Intermittent cryogen spray cooling for optimal heat extraction during dermatologic laser treatment[J].Physics in medicine and biology,2002(18):3275-3288. |
[7] | Aguilar G;Franco W;Liu J;Svaasand LO;Nelson JS .Effects of hypobaric pressure on human skin: implications for cryogen spray cooling (part II).[J].Lasers in surgery and medicine,2005(2):130-135. |
[8] | Karapetian E;Aguilar G;Kimel S;Lavernia EJ;Nelson JS .Effects of mass flow rate and droplet velocity on surface heat flux during cryogen spray cooling.[J].Physics in medicine and biology,2003(1):N1-6. |
[9] | Jia W;Aguilar G;Wang GX;Nelson JS .Heat-transfer dynamics during cryogen spray cooling of substrate at different initial temperatures.[J].Physics in medicine and biology,2004(23):5295-5308. |
[10] | Kao B;Kelly KM;Aguilar G;Hosaka Y;Barr RJ;Nelson JS .Evaluation of cryogen spray cooling exposure on in vitro model human skin.[J].Lasers in surgery and medicine,2004(2):146-154. |
[11] | 周致富,辛慧,陈斌,王国祥.激光手术喷雾冷却中单个液滴蒸发特性[J].中国激光,2008(06):952-956. |
[12] | 刘俊峰,陈斌,王国祥,王跃社.水射流冷却过程中表面热流密度的预测[J].工程热物理学报,2010(01):110-112. |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%