某国产600MW核电机组在停堆检修过程中,发现位于汽轮机高压缸主蒸汽入口主调门油动饥活塞杆已经断裂.通过分析活塞杆的材料、显微组织、力学性能和断口等,并结合活塞杆制造的资料等信息,分析了造成活塞杆断裂的原因.
In the process of shutdown maintenance of a 600 MW nuclear power unit, it was found that one of the connected rods in the main control valves at the upstream of the high pressure cylinder had been breakdown. The investigation for the failure including chemical composition analysis, microstructure observation, mechanical property measurement and the fracture patterns examination of the connected rod was taken and the relevant failure machanisum was proposed.
参考文献
[1] | 崔忠圻.金属学与热处理[M].北京:机械工业出版社,1995. |
[2] | 王广生.金属热处理缺陷分折及案例[M].北京:机械工业出版社,1997. |
[3] | 成大先.机械设计手册[M](第4版).北京:化学工业出版社,2004. |
[4] | 吴宗泽.机械设计师手册[M].北京:机械工业出版社,2006. |
[5] | 钟群鹏,赵子华.断口学[M].北京:高等教育出版社,2006. |