基于某微燃机构建了HAT循环,研究了其在功率下降(ISO条件)、环境温度变化时的变工况性能,并与简单循环、回热循环和RWI(注水回热)循环的设计工况、变工况性能进行了对比.结果表明,HAT循环和RWI循环的变工况性能相似且好于简单循环和回热循环.其中,空气湿化程度的调整对于HAT循环变工况性能的稳定性起重要作用.但由于没有设置中冷器,且微燃机循环中可资利用的(火用)较少,HAT循环设计工况和变工况性能相对于其它循环的优势没有得到充分体现.
参考文献
[1] | Maria Jonsson;Jinyue Yan .Humidified gas turbines—a review of proposed and implemented cycles[J].Energy,2005(7):1013-1078. |
[2] | 赵丽凤,肖云汉,张世铮.环境温度对湿空气透平(HAT)循环性能的影响[J].热能动力工程,2002(02):122-125. |
[3] | Houck C R;Joines J A;Kay M G .A Genetic Algorithm for Function Optimization:A Matlab Implementation[D].North Carolina State University,1995. |
[4] | Erbes M R;Phillips J N.Modeling the Off-Design Perfor mance of Power Plants for Systems Studies:Issues and Methodologies[A].Boston,1987 |
[5] | Erbes M R;Gay R R;Cohn A.A Simulation Code for the Analysis of Gas-Turbine Power Plants.1989 International Gas Turbine Conference and Exposition[M].Toronto,Ontario,Canada,1989 |
[6] | Mathieu P;Greday Y F.Transient Behavior of a Humid Air Turbine[A].北京,1997 |