通过差示扫描量热技术,研究了热循环对Cu-23.6Zn-4.47Al-0.23Mn-0.17Ni形状记忆合金中双可逆相变的影响.结果表明,X→M转变温度随热循环的进行而降低,而马氏体逆转变的温度几乎不发生变化.
The influence of thermal cycling on double reversible transformations in the Cu-23.6Zn-4.47Al-0.23Mn-0.17Ni shape memory alloy was investigated by differential scanning calorimetry. It is found that the temperatures of the X→M transition drop down with the progress of thermal cycling, while those of the reverse martensitic transformation almost have no change.
参考文献
[1] | Friend C M;Ortin J;Planes A;Manosa Ll,Yoshikawa M .[J].Scripta Metallurgica et Materialia,1990,24:1641. |
[2] | Xu H B;Tan S S .[J].Scipta Metallurgic et Materialia,1995,33:749. |
[3] | Morawiec H;Stroz D;Goryczka T;Chrobak D .[J].Scripta Materialia,1996,35:485. |
[4] | Da Silva E P .[J].Materials Letters,1999,38:341. |
[5] | Geng Guili;Bai Yujun;Wang Shuhua .[J].Materials Characterization,1999,42:45. |
[6] | Kwarciak J .[J].Thermochimica Acta,1986,106:209. |
[7] | Bai Yujun;Geng Guili;Sun Dongsheng;Bian Xiufang, Wang Shouren .[J].Journal of Physics:Condensed Matter,2000,12:L61. |
[8] | Bai Yujun;Geng Guili;Bian Xiufang;Sun Dongsheng Wang Shouren .[J].Materials Science and Engineering A,2000,284:25. |
[9] | BAI Yu-jun,SUN Dong-sheng,GENG Gui-li,BIAN Xiu-fang.Double reversible transformations under various treatment states[J].中国有色金属学会会刊,2000(01):47. |