高级检索

本文针对LOFTL2-5整体试验,用先进热工水力程序RELAP5/MOD3对其进行最佳估算模拟,分析验证了程序预测事故过程的能力;同时按照美国核管会10CFR50.46附录K的认证评价模型要求修改RELAP5/MOD3相关模型并进行模拟计算,通过对比程序修改前后对于预测值保守性的影响,分析了保守计算的PGT安全裕量,其结果可为验证并开发认证级LOCA安全分析工具提供参考.

参考文献

[1] Nuclear Safety Analysis Division.RELAP5/MOD3.3 Code Manual[M].USA:Information Systems Laboratories.Inc.Rockville,Maryland,2001
[2] Bayless P D;Divine J M.Experiment Data Report for LOFT Large Break Loss-of-Coolant Experiment L2-5[M].USA:Idaho Operations Office,Idaho National Engineering Laboratory,1982
[3] EJ332-1988.EJ332-1988.压水堆核电厂应急堆芯冷却系统设计准则[S].,1988.
[4] US Nuclear Regulatory Commission.Acceptance Criteria for Emergency Core Cooling Systems for Light Water Nuclear Power Reactors,Appendix K,ECCS Evaluation Models.10CFR50.46[M].Washington:US Govt.Printing office,1992
[5] Moody F J .Maximum Flow Rate of a Single Component Two-Phase Mixture[J].Journal of Heat Transfer,Transactions of the ASME,1965,87(01):134-142.
[6] Groeneveld D C;Cheng S C;Doan T D .1986 AECL-UO Critical Heat Flux Lookup Table[J].Heat Transfer Engineering,1986,7:46-62.
[7] Gellerstedt J L.Correlation of Critical Heat Flux in a Bundle Cooled by Pressurized Water,Two-Phase Flow and Heat Transfer in Rod Bundles Symposium[A].California:Los Angeles,1969:63-71.
[8] Barnett P G .A Correlation of Burnout Data for Uniformly Heated Annuli and Its Use for Predicting Burnout in Uniformly Heated Rod Bundles[England:AEEW-R463][R].,1966.
[9] Hughe E D.A Correlation of Rod Bundles Critical Heat Flux for Water in the Pressure Range 150 to 725 psia[M].USA:Idaho Nuclear Corporation,1970