欢迎登录材料期刊网

材料期刊网

高级检索

A 1:2.5 scale tundish model was set up in laboratory for a six-strand billet continuous casting tundish with different configurations to investigate fluid flowing characteristics under different operational conditions by measuring residence time distribution curves. It was known from the investigation that minimum residence time, maximum concentration time and average residence time of the three strands in the same side of the tundish with the former configuration under normal operation, that is, 6 strands were open, were small and non-uniform and the tundish had large dead volume fraction. Vortexes easily formed on the liquid surface in the pouring zone of the tundish. The fluid flow characteristics in the tundish with the optimal turbulence inhibitor and baffles were improved and became less non-uniform among the strands. Vortexes were not found on the pouring zone surface in the optimal tundish. Under un-normal operation, that is, one strand was close, it was important to choose which strand should be closed for flowing characteristics of the rest two strands. It was found from this investigation that fluid flowing characteristics in the optimal configuration tundish with closing strand 2 were better than those with closing strand 3 at the same side.