镁及其合金具有在生物体内可生物降解吸收的特点,然而镁及其合金在体内过快的腐蚀降解速率成为限制其医学应用的关键科学问题.在合金表面制备可生物降解表面涂层是提高镁及其合金体内耐蚀性能的重要途径.为此,系统地综述了植入用镁合金可生物降解涂层的种类和制备方法,分析了各种涂层的优缺点,并指出其存在的问题和今后的研究方向.

参考文献

[1] Staiger MP;Pietak AM;Huadmai J;Dias G .Magnesium and its alloys as orthopedic biomaterials: A review[J].Biomaterials,2006(9):1728-1734.
[2] Wolf Federica I et al.Chemistry and biochemistry of magnesium[J].Molecular Aspects Medicine,2003,24(1-3):3.
[3] Hartwig A .Role of magnesium in genomic stability.[J].Mutation Research: International Journal on Mutagenesis, Chromosome Breakage and Related Subjects,2001(1/2):113-121.
[4] Okuma T .Magnesium and bone strength[J].NUTRITION,2001,17(7-8):679.
[5] Heublein B et al.Biocorrosion of magnesium alloys:A new principle in cardiovascular implant technology[J].HEART,2003,89(6):651.
[6] Dingchuan Xue,Yeoheung Yun,Zongqing Tan,Zhongyun Dong,Mark J. Schulz.In Vivo and In Vitro Degradation Behavior of Magnesium Alloys as Biomaterials[J].材料科学技术学报:英文版,2012(03):261-267.
[7] L. Yang;N. Hort;R. Willumeit;F. Feyerabend .Effects of corrosion environment and proteins on magnesium corrosion[J].Corrosion Engineering, Science and Technology,2012(5):335-339.
[8] 洪岩松,杨柯,张广道,黄晶晶,郝玉全,艾红军.可降解镁合金的动物体内骨诱导作用[J].金属学报,2008(09):1035-1041.
[9] Sannakaisa Virtanen .Biodegradable Mg and Mg alloys: Corrosion and biocompatibility[J].Materials Science & Engineering, B. Solid-State Materials for Advanced Technology,2011(20):1600-1608.
[10] Waizy, H.;Seitz, J.-M.;Reifenrath, J.;Weizbauer, A.;Bach, F.-W.;Meyer-Lindenberg, A.;Denkena, B.;Windhagen, H. .Biodegradable magnesium implants for orthopedic applications[J].Journal of Materials Science,2013(1):39-50.
[11] Z. Grubac;I. Skugor Roncevic;M. Metikos-Hukovic .Surface Modification of Biodegradable Magnesium Alloys[J].Journal of the Electrochemical Society,2012(6):C253-C258.
[12] H. Wang;Y. Estrin;Z. Zuberova .Bio-corrosion of a magnesium alloy with different processing histories[J].Materials Letters,2008(15):2476-2479.
[13] Xin Renlong et al.Effect of microstructure and texture on corrosion resistance of magnesium alloy[J].Mater Res,2009,610-613:1160.
[14] 颜廷亭 .AZ31B镁合金的生物医用表面改性研究[D].南京理工大学,2010.
[15] N. T. Kirkland .Magnesium biomaterials: past, present and future[J].Corrosion Engineering, Science and Technology,2012(5):322-328.
[16] Jiali Wang;Jian Tang;Peng Zhang;Yangde Li;Jue Wang;Yuxiao Lai;Ling Qin .Surface modification of magnesium alloys developed for bioabsorbable orthopedic implants: A general review.[J].Journal of biomedical materials research, Part B. Applied biomaterials,2012(6):1691-1701.
[17] Lorenz C;Brunner JG;Kollmannsberger P .Effect of surface pre-treatments on biocompatibility of magnesium.[J].Acta biomaterialia,2009(7):2783-2789.
[18] Yang,J.X.;Cui,F.Z.;Lee,I.-S.;Zhang,Y.;Yin,Q.S.;Xia,H.;Yang,S.X. .In vivo biocompatibility and degradation behavior of Mg alloy coated by calcium phosphate in a rabbit model[J].Journal of biomaterials applications,2012(2):153-164.
[19] Xu L;Pan F;Yu G;Yang L;Zhang E;Yang K .In vitro and in vivo evaluation of the surface bioactivity of a calcium phosphate coated magnesium alloy.[J].Biomaterials,2009(8):1512-1523.
[20] Song, Y.;Shan, D.;Han, E.-H. .A novel biodegradable nicotinic acid/calcium phosphate composite coating on Mg-3Zn alloy[J].Materials science & engineering, C. Biomimetic and supramolecular systems,2013(1):78-84.
[21] Song Y W et al.Electrodeposition of hydroxyapatite coating on AZ91D magnesium alloy for biomaterial application[J].Materials Letters,2008,62(17-18):3276.
[22] Characterization and degradation behavior of AZ31 alloy surface modified by bone-like hydroxyapatite for implant applications[J].Applied Surface Science: A Journal Devoted to the Properties of Interfaces in Relation to the Synthesis and Behaviour of Materials,2009(13/14):6433.
[23] Bakhsheshi-Rad, H.R.;Idris, M.H.;Abdul-Kadir, M.R..Synthesis and in vitro degradation evaluation of the nano-HA/MgF_2 and DCPD/MgF_2 composite coating on biodegradable Mg-Ca-Zn alloy[J].Surface & Coatings Technology,2013:79-89.
[24] Jo,J.-H.;Hong,J.-Y.;Shin,K.-S.;Kim,H.-E.;Koh,Y.-H. .Enhancing biocompatibility and corrosion resistance of Mg implants via surface treatments[J].Journal of biomaterials applications,2012(4):469-476.
[25] Adjustment of the ratio of Ca/P in the ceramic coating on Mg alloy by plasma electrolytic oxidation[J].Applied Surface Science: A Journal Devoted to the Properties of Interfaces in Relation to the Synthesis and Behaviour of Materials,2009(13/14):6724.
[26] Abhijit Roy;Satish S. Singh;Moni Kanchan Datta .Novel sol-gel derived calcium phosphate coatings on Mg4Y alloy[J].Materials Science & Engineering, B. Solid-State Materials for Advanced Technology,2011(20):1679-1689.
[27] Chiu KY;Wong MH;Cheng FT;Man HC .Characterization and corrosion studies of fluoride conversion coating on degradable Mg implants[J].Surface & Coatings Technology,2007(3):590-598.
[28] M. Carboneras;M.C. Garcia-Alonso;M.L Escudero .Biodegradation kinetics of modified magnesium-based materials in cell culture medium[J].Corrosion Science: The Journal on Environmental Degradation of Materials and its Control,2011(4):1433-1439.
[29] Witte F;Fischer J;Nellesen J;Vogt C;Vogt J;Donath T;Beckmann F .In vivo corrosion and corrosion protection of magnesium alloy LAE442.[J].Acta biomaterialia,2010(5):1792-1799.
[30] Fukumoto S et al.Improvement of corrosion resistance and adhesion of coating layer for magnesium alloy coated with high purity magnesiurr[J].MATERIALS TRANSACTIONS,2003,44(4):518.
[31] Guosong Wu;Ruizhen Xu;Kai Feng;Shuilin Wu;Zhengwei Wu;Guangyong Sun;Gang Zheng;Guangyao Li;Paul K. Chu .Retardation of surface corrosion of biodegradable magnesium-based materials by aluminum ion implantation[J].Applied Surface Science: A Journal Devoted to the Properties of Interfaces in Relation to the Synthesis and Behaviour of Materials,2012(19):7651-7657.
[32] Li, J.N.;Cao, P.;Zhang, X.N.;Zhang, S.X.;He, Y.H. .In vitro degradation and cell attachment of a PLGA coated biodegradable Mg-6Zn based alloy[J].Journal of Materials Science,2010(22):6038-6045.
[33] J. H. Gao;X. Y. Shi;B. Yang;S. S. Hou;E. C. Meng;F. X. Guan;S. K. Guan .Fabrication and characterization of bioactive composite coatings on Mg-Zn-Ca alloy by MAO/sol-gel[J].Journal of Materials Science. Materials in Medicine,2011(7):1681-1687.
[34] Wong HM;Yeung KW;Lam KO;Tam V;Chu PK;Luk KD;Cheung KM .A biodegradable polymer-based coating to control the performance of magnesium alloy orthopaedic implants.[J].Biomaterials,2010(8):2084-2096.
[35] Xu X H et al.Cross-linked gelatin/nanoparticles composite coating on micro-arc oxidation film for corrosion and drug release[J].Applied Surface Sinence,2010,256(8):2367.
[36] Hahn, B.-D.;Park, D.-S.;Choi, J.-J.;Ryu, J.;Yoon, W.-H.;Choi, J.-H.;Kim, H.-E.;Kim, S.-G. .Aerosol deposition of hydroxyapatite-chitosan composite coatings on biodegradable magnesium alloy[J].Surface & Coatings Technology,2011(8/9):3112-3118.
[37] Hu Rong Gang et al.Recent progress in corrosion protection of magnesium alloys by organic coatings[J].Progress in organic Coatings,2012,73(2-3):129.
[38] Rosemann P et al.Short and long term degradation behaviour of Mg-1Ca magnesium alloys and protective coatings based on plasma-chemical oxidation and biodegradable polymer coating in synthetic body fluid[J].Mater Corr-Werkstoffe Und Korrosion,2013,64(8):714.
[39] Wang Hongju et al.Electrochemical property and in vitro degradation of DCPD-PCL composite coating on the biodegradable Mg-Zn alloy[J].Materials Letters,2012,68:435.
[40] Jemimah Walker;Shaylin Shadanbaz;Nicholas T Kirkland;Edward Stace;Tim Woodfield;Mark P Staiger;George J Dias .Magnesium alloys: predicting in vivo corrosion with in vitro immersion testing.[J].Journal of biomedical materials research, Part B. Applied biomaterials,2012(4):1134-1141.
[41] Xin Y;Hu T;Chu PK .In vitro studies of biomedical magnesium alloys in a simulated physiological environment: a review.[J].Acta biomaterialia,2011(4):1452-1459.
[42] 宋光铃,宋诗哲.镁在人体模拟液中的腐蚀行为[J].物理化学学报,2006(10):1222-1226.
[43] 王勇,高家诚,张艳,周详发,伍沙.纯镁在模拟体液中的腐蚀机理[J].中国有色金属学报,2007(12):1981-1986.
[44] Assessing the corrosion of biodegradable magnesium implants: A critical review of current methodologies and their limitations[J].Acta biomaterialia,2012(3):925-936.
[45] Perez de Prado Armando et al.Preclinical evaluation of coronary stents:Focus on safety issues[J].Current Vascular Pharmacology,2013,11(1):74.
上一张 下一张