介绍了加速器驱动次临界系统(ADS)注入器Ⅱ束流聚焦单元超导螺线管的初步测试。该测试在高度1600mm、直径510mm的垂直杜瓦中,利用型号为cryogenicsms的超导电源对磁体进行了励磁,并利用霍尔探头测试了其轴向磁场分布情况和漏场情况,其中心磁场励磁后可达8.20T,漏场分布和计算值的相对误差小于10%。同时,对励磁过程中骨架的应力应变状态做了测试。对测试结果的分析表明,骨架结构设计合理,应变状态变化平稳,磁体低温稳定性能良好。
The preliminary test of the superconducting solenoid for ADS injector tl has been carried out in order to measure its performances. A vertical dewar with height 1 600 mm and outer diameter 510 mm was employed for this test. The magnet was energized by a cryogenic sms superconducting magnet current source. The axial magnetic distribution and leakage field were also tested through hall probes. The center field can be excited up to 8.20 T and the relative diviation between the measured value and the calculated value of the stray and leakage field is less than 10%. The measurements of the strain and stress status of the magnet skeleton show that the distortion is small and the mechanical performance is robust.
参考文献
[1] | WANG Zhijun, HE Yuan, LIU Yong, et al. Chinese Physics C, 2012, in press. |
[2] | SUN Hong, ZHAO Shengchu, GE Mingqi, etal. Chinese Physics C, 2005, 29(10): 989. |
[3] | YANG Xiaoliang, MA Lizhen,Wu Wei, et al. Chinese Physics C, 2012. |
[4] | WU Wei, HE Yuan, MA Lizhen, et al. Chinese Physics C, 2010, 84(7): 978. |
[5] | Cryoperm Specifications[EB/OL:. [2012-01-05:. http:// www. cryopermshielding, com/cryoperm-specifications, html. |
- 下载量()
- 访问量()
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%