采用原子力显微镜(AFM)和X射线衍射分析(XRD)研究了退火处理对TiNi合金钽镀层微观组织结构的影响,研究表明:采用多弧离子镀在TiNi合金表面沉积得到了β-Ta镀层,经退火处理后,钽镀层的表面粗糙度增加,亚稳定的β-Ta相完全转变为稳定的α-Ta相.采用血小板粘附试验研究了退火对镀钽TiNi合金血液相容性的影响.发现经过退火处理后血小板粘附数量明显降低,血小板没有发生聚集和变形,只有少数长出了伪足,即血小板基本未被激活,说明退火改善了镀钽TiNi合金的血液相容性.
参考文献
[1] | Otsuka K;Wayman C M.Shape Memory Materials[M].Cambridge University Press,1994:220-239. |
[2] | Wu SK.;Lin HC. .Recent development of TiNi-based shape memory alloys in Taiwan[J].Materials Chemistry and Physics,2000(2):81-92. |
[3] | 赵连城;蔡伟;郑玉峰.合金的形状记忆效应与超弹性[M].北京:国防工业出版社,2002:339-382. |
[4] | Duerig T W;Tolomea D E;Wholey M .An overview of superelastic stent design[J].Minimal Invasive Therapy and Allied Technology,2000,9:235-246. |
[5] | Violaris A G;Ozaki Y;Serrys P W .Endovascular Stents:a 'Break Through Technology',Future Challenges[J].International Journal of Cardiovascular Imaging,1997,13:3-13. |
[6] | Ryhanen J .Biocompatibility Evaluation of Nickel-Titanium Shape Memory Metal Alloy[D].Dissertation of Oulu University,1999. |
[7] | 杨大智;吴明雄.Ni-Ti形状记忆合金在生物医学领域的应用[M].北京:冶金工业出版社,2003:57-60. |
[8] | Shabalovskaya SA .Surface, corrosion and biocompatibility aspects of Nitinol as an implant material.[J].Bio-medical materials and engineering,2002(1):69-109. |
[9] | Jianlu MA;Jiangnan Liu;Zhengpin Wang .Effects of Ta Addition on NiTi Shape Memory Alloys[J].Journal of Materials Science & Technology,2000(5):534-536. |
[10] | Hodgson D E;Smith S A.Augmented Properties of NiTi Wire by "Filling"with Selected Metals[A].,1997:461-465. |
[11] | R. Steegmueller;C. Wagner;T. Fleckenstein .Gold Coating of Nitinol Devices for Medical Applications[J].Materials Science Forum,2002(0):161-164. |