本文介绍一台20 K以下温区斯特林型脉冲管制冷机的最新研制结果,制冷机采用压缩机与脉冲管耦合在一起的一体式结构,蓄冷器和脉冲管采用同轴布置形式,制冷机整机质量15.5 kg.实验发现分别以最低温度和最大制冷量为优化目标所对应的双向开度存在着略微的区别.在250 W的输入电功下,双向开度以最低温度为优化目标时,尢负荷最低温度14.7 K,是目前单级结构斯特林型脉冲管制冷机最低温度的一个新纪录;当双向开度略微减小以后,无负荷最低温度上升到15.4 K,但在20 K的制冷量从365 mW提高至398mW.
参考文献
[1] | L.W.Yang;Y.Q,Xun;G.Thummes .Single-stage high frequency coaxial pulse tube cryocooler with base temperature below 30 K[J].Cryogenics,2010(5):342-346. |
[2] | 荀玉强,杨鲁伟,蔡京辉,梁惊涛,周远.30 K单级高频同轴脉冲管制冷机[J].工程热物理学报,2009(05):734-736. |
[3] | LM. Qiu<D.Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, PR China;X.Q. Zhi<D.Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, PR China;L Han<D.Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, PR China .Performance improvement of multi-stage pulse tube cryocoolers with a self-precooled pulse tube[J].Cryogenics,2012(10):575-579. |
[4] | Pengda Yan;Guobang Chen;Jingjing Dong .15 K two-stage Stirling-type pulse-tube cryocooler[J].Cryogenics,2009(2):103-106. |
[5] | 赵密广,杨鲁伟,梁惊涛.16.1 K的高频两级脉冲管制冷机的实验研究[J].工程热物理学报,2007(02):205-207. |
[6] | 金海,朱文秀,王俊杰,周远,陈六彪.19.3K单级高频脉冲管制冷机的实验研究[J].工程热物理学报,2012(07):1119-1121. |
[7] | Liubiao Chen;Hai Jin;Junjie Wang.18.6 K single-stage high frequency multi-bypass coaxial pulse tube cryocooler[J].Cryogenics,2013:54-58. |
[8] | 陈六彪,金海,朱文秀,王俊杰,周远,顾开选,季伟.0.2 W@20.6 K单级高频脉冲管制冷机研究[J].工程热物理学报,2013(04):587-590. |