对失效的冷凝器管板进行分析认为,其腐蚀原因为硫 酸的露点腐蚀,并提出了改进措施.
Failure analysis has been made for a tube sheet of a condenser with X-ray diffra ctometer, scan electron microscope(SEM),optical microscope, and chemical analysi s.Failure of the tube sheet was caused by sulphuric-acid dew corrosion.Measureme nts of improving are also proposed.