针对高电荷态离子与表面作用产生的溅射离子能谱测量,研制了一台127°径向位置灵敏柱形静电离子能谱仪.利用能量为800 keV的Ar8+离子轰击金属铍靶产生的溅射离子测试了本谱仪.测试结果表明,该谱仪克服了传统静电谱仪通过扫描工作电压单能量点取谱的缺点,实现分段取谱--在单个工作电压下可同时获取一段0.85Ec≤E≤1.15Ec范围的能谱,从而提高测量效率.
参考文献
[1] | Hughes A L,Rojansky V.Phys Rev,1929,34:284. |
[2] | Arnow M M,Jones D R.Rev Sci Instr,1972,43:72. |
[3] | Purcell E M.Phys Rev,1938,54:818. |
[4] | Theodoridis G C,Paolini F R.Rev Sci Instr,1969,40:621. |
[5] | Decreau P,Prange R,Berthelier J J.Rev Sci Instr,1975,46:995. |
[6] | Sar-El H Z.Rev Sci Instr,1967,38:1210. |
[7] | Hafner H,Simpson J A,Kuyatt C E.Rev Sci Instr,1968,39:33. |
[8] | Aksela S,Karras M,Pessa M,et al.Rev Sci Instr,1970,41:351. |
[9] | Sar-El H Z.Rev Sci Instr,1971,42:1601. |
[10] | Behrisch Rainer,Eckstein Wolfgang.Sputtering by Particle Bombardment-Experiments and Computer Calculations from Threshold to MeV Energies.Springer Berlin/Heidelberg,2007. |