针对目前严峻的电子组件散热形势,制造了高热流密度传热组件-均温板,并对其传热特性进行了研究.实验表明该均温板可承受非常高的热流密度.当加热功率达到170W时,热流密度超过了40W/cm2,均温板的上底面最高温度不超过85℃,从而表现出良好的均温和散热特性.热阻随加热功率的增大而减小,并逐渐趋于平缓.

参考文献

[1] Yen-Shu Chen;Kuo-Hsiang Chien;Chi-Chuan Wang;Tzu-Chen Hung;Yuh-Ming Ferng;Bau-Shei Pei .Investigations of the Thermal Spreading Effects of Rectangular Conduction Plates and Vapor Chamber[J].Journal of Electronic Packaging: Transactions of the ASME,2007(3):348-355.
[2] Go JS .Quantitative thermal performance evaluation of a cost-effective vapor chamber heat sink containing a metal-etched microwick structure for advanced microprocessor cooling[J].Sensors and Actuators, A. Physical,2005(2):549-556.
[3] YASUSHI KOITO;HIDEAKI IMURA;MASATAKA MOCHIZUKI;YUJI SAITO;SHUICHI TORII .Fundamental Experiments and Numerical Analyses on Heat Transfer Characteristics of a Vapor Chamber: Effect of Heat Source Size[J].JSME International Journal, Series B. Fluids and Thermal Engineering,2006(4):1233-1240.
[4] Lee;S H K;Chu S K;Choi C C C.Performance Characteristics of Vapor Chambers with Boiling Enhanced Multi-Wick Structures[M].San Jose,CA,United States:Institute of Electrical and Electronics Engineers Inc.Piscataway,NJ 08855-1331,United States,2007
[5] Minhua Lu;Larry Mok;R. J. Bezama .A Graphite Foams Based Vapor Chamber for Chip Heat Spreading[J].Journal of Electronic Packaging: Transactions of the ASME,2006(4):427-431.
[6] Vadakkan U;Chrysler G M;Sane S.Silicon/Water Vapor Chamber as Heat Spreaders for Microelectronic Packages[M].San Jose,CA,United States:Institute of Electrical and Electronics Engineers Inc,Piscataway,NJ 08855-1331,United States,2005
[7] Wei J;Chan A;Copeland D.Measurement of Vapor Chamber Performance[M].San Jose,CA,United States:Institute of Electrical and Electronics Engineers Inc,2003
[8] Wu X P;Mochizuki M;Nguyen T.Low Profile High Performance Vapor Chamber Heat Sinks for Cooling High-Density Blade Servers[M].San Jose,CA,United States:Institute of Electrical and Electronics Engineers Inc,Piscataway,NJ 08855-1331,United States,2007
[9] Zuo,Z J;Dussinger P M.Heat Pipe Vapor Chamber Cold Plate Modeling,Fabrication and Testing[M].Anaheim,CA,USA:ASME,Fairfield,N J,USA,1998