本文用数值计算和实验测量结合的实验方法对冷却条件下超临界压力二氧化碳在细圆管内(Din=2 mm)的局部对流换热进行了实验研究.结果表明,冷却条件下超临界二氧化碳局部对流换热系数在流体温度略高于准临界温度时达到峰值.本文还对该过程进行了数值模拟,比较了不同湍流模型的计算结果,根据数值模拟提供的信息分析了影响冷却条件下超临界压力二氧化碳换热的主要因素和物性变化对换热的影响.
参考文献
[1] | W B Hall .Heat Transfer Near the Critical Point[J].Advance in Heat Transfer,1971,7:85. |
[2] | B S Petukhov .Heat Transfer and Friction in Turbulent Pipe Flow with Variable Physical Properties[J].Advance in Heat Transfer,1970,6:03-564. |
[3] | A F Polyakov.Heat Transfer under Supercritical Pressures[J].Advance in Heat Transfer,1991:21-53. |
[4] | Krasnoshchekov E A;Protopopov V S .Experimental Study of Heat Exchange in Carbon Dioxide in the Supercritical Range at High Temperature Drops (in Russian)[J].Teplofizika Vysokikh Temperature,1966,4(03):389-398. |
[5] | Baskov V L;I V Kuraeva;V S Protopopov .Heat Transfer with the Turbulent Flow of a Liquid at Supercritical Pressure in Tube under Cooling Condition[J].Teplofizika Vysokikh Temperature,1977,15(01):96-102. |
[6] | Additional Turbulence Models in FLUENT[M].Fluent Inc,2003 |