研究了基于PMMA波导的乐甫波传感器,研究了器件的插损以及质量灵敏度随波导层厚度变化的关系.采用低浓度、低粘度的前驱溶液,多步旋涂工艺制备了PMMA波导薄膜,降低了器件的插损,实现了2.18/μm的"有效厚度",器件的质量灵敏度达705cm2/g,与前人相比提高了1倍.
参考文献
[1] | Wang Z;Cheeke J D N;Jen C K .[J].Applied Physics Letters,1994,64:2940. |
[2] | Gizeli E;Stevenson A C;Goddard N J et al.[J].Sensors and Actuators B:Chemical,1992,6:131. |
[3] | Turton A;Bhattacharyya D;Wood D .[J].Measurement Science and Technology,2006,17:257. |
[4] | McHale G;Newton M I;Martin F .[J].Applied Physics Letters,2001,79:3542. |
[5] | Josse F;Bender F;Cernosek RW .Guided shear horizontal surface acoustic wave sensors for chemical and biochemical detection in liquids[J].Analytical chemistry,2001(24):5937-5944. |
[6] | Du J.;Harding GL. .A multilayer structure for Love-mode acoustic sensors[J].Sensors and Actuators, A. Physical,1998(2/3):152-159. |
[7] | 杜晓松;蒋亚东;杨邦朝 等.[J].功能材料,2007,38 |
[8] | Bender F.;Josse F.;Cernosek RW. .Love-wave biosensors using cross-linked polymer waveguides on LiTaO3 substrates[J].Electronics Letters,2000(19):1672-1673. |