通过交变电磁场磁化液体聚合硫酸铁(PFS)混凝剂,研究了磁化混凝的工艺条件及除藻性能.结果表明,在PFS投药量80 mg/L、电流强度1.0A、频率75 Hz、磁化时间3min、pH=8的条件下,处理效果最好,小球藻的去除率达90.7%.与常规混凝相比,磁化混凝的混凝剂用量节省了12.5%,除藻率提高了5.7%.磁化混凝工艺具有处理效率更高、投药量更少、污泥性能更好等优点.并初步解释了磁化混凝除藻的机理.
参考文献
[1] | A new inorganic-organic composite coagulant, consisting of Polyferric Sulphate (PFS) and Polyacrylamide (PAA)[J].Water research: A journal of the international water association,2009(14):3511-3524. |
[2] | Dan Liu;Peng Wang;Guanran Wei .Removal of algal blooms from freshwater by the coagulation-magnetic separation method[J].Environmental Science and Pollution Research,2013(1):60-65. |
[3] | 徐灏龙,王长智.磁性混凝剂的制备及其在磁过滤工艺中的应用[J].中国给水排水,2011(09):88-90. |
[4] | Sergej Knez;Ciril Pohar .The magnetic field influence on the polymorph composition of CaCO_3 precipitated from carbonized aqueous solutions[J].Journal of Colloid and Interface Science,2005(2):377-388. |
[5] | 迟金宝,邢奕,苍大强,宋存义,张雪峰.磁场水处理技术中微观电磁感应行为分析[J].环境工程,2009(04):20-24. |
[6] | R. K. Henderson;S. A. Parsons;B. Jefferson .Successful Removal of Algae through the Control of Zeta Potential[J].Separation Science and Technology,2008(7):1653-1666. |