通过对一级探伤钢种探伤合格率低的原因进行分析,在夹杂物控制、RH真空度、过热度、拉速、铸坯加热时间、压下量等方面采取措施后,探伤合格率得到了明显提高。
By analyzing the low flaw detection passing rate of class-Ⅰsteel plate,after taking measures of inclusion,vacuum degree of RH,superheat,speed,slab heating time and rolling reduction,etc.,the qualified rat of flaw detection has been improved remarkably.
参考文献
[1] | 王杰,鞠传华,陈福山,王新刚,乔孟平.低合金中厚板探伤不合原因分析及对策[J].宽厚板,2009(04):6-8. |
[2] | 孙齐松,王新华,许晓东,江东才,白学军.铸坯在加热炉停留时间对中厚板探伤合格率的影响[J].北京科技大学学报,2008(05):492-494,500. |