本研究采用光学显微镜(OM),扫描电镜(SEM),能谱分析(EDS)和透射电镜(TEM)等实验技术,分别对2205双相不锈钢在700℃,750℃时效处理0.5h、1h、2h后组织中的析出相进行分析;结果表明,在700℃时效处理的条件下,2205双相不锈钢的析出相主要是Cr2N和χ相;750℃时效处理的条件下,析出相主要由Cr2N、χ相以及σ相组成。结合室温冲击功的测量结果,随时效时间的延长,该钢的冲击功明显降低;在相同时效时间条件下,与700℃时效处理相比,经750℃时效处理后的2205钢冲击功较低,这主要是由于组织中σ相的析出造成的。

A serial ageing treatments of 2205 duplex stainless steel(DSS) at the temperature of 700℃ and 750℃ for different time intervals (0.5h,1h,2h) were carried out. Aided by optical metallography, SEM&EDS and TEM analysis, the evolution of precipitation in 2205DSS during aging treatment was determined. The results showed that the main type of precipitation in 2205DSS was Cr2N, χ phase at 700℃ aging and Cr2N, χ and σ phase at 750℃ aging. Combined with impact toughness experimental results, it was shown that the impact energy of 2205 DSS decreased with prolonged keeping time; in addition, the impact energy of 2205 DSS at 750 aging was lower than that at 700℃ aging due to the σ phase precipitated in microstructure of 2205 DSS.