采用扫描电镜、X 射线衍射、极化曲线测量、电化学阻抗谱、中性盐雾试验等方法,考察了内部经磷化的轨道车辆供风管运行5年后的腐蚀情况,对9处不同部位风管取样并与新风管对比,确定了磷化膜及腐蚀产物的组成,分析了腐蚀发生的原因。制动控制处风管因长期处于高风速的送风应力及灰尘冲刷作用之下而受到严重腐蚀,车钩管因高温弯管加工后磷化膜脱落而发生了一定程度的氧化,紧急通风管因与潮湿空气接触而发生轻微腐蚀。针对上述情况,提出了相应的解决措施,并强调要加强管材的质量管理。

The corrosion of ventilation pipes phosphated inside after using in railway vehicles for five years was examined by scanning electron microscopy, X-ray diffraction, polarization curve measurement, electrochemical impedance spectroscopy, and neutral salt spray test. The samples taken from nine positions of ventilation and pneumatic pipes system were compared with the unused ones. The compositions of phosphating films and corrosion products were determined. The causes of corrosion were analyzed. The pipe in brake control unit (BCU) suffered a serious erosion under the continuous high pressure of air supply and the presence of dust. The air pipe in coupler was subjected to oxidation at a certain degree due to the exfoliation of phosphating films after high- temperature bending. The pipe for emergency air supply was slightly corroded in a humid environment. Some remedies were presented and the quality control of phosphated pipes was highlighted.

参考文献

[1] 曹亚楠 .高速动车组空调通风系统数值仿真及分析[D].大连:大连交通大学,2009.
[2] MASAYUKI MIYAMOTO.日本高速列车先进技术的近期研究与发展(待续)[J].国外铁道车辆,2004(02):1-8.
[3] 冈本勋.日本新干线列车技术发展趋势[J].国外铁道车辆,2003(04):4-7.
[4] 刘安.城轨车辆供风系统用风量计算及验证试验[J].机车电传动,2010(05):62-66.
[5] 马立.日本铁道车辆转向架的研究与发展历程[J].铁道机车车辆,2010(06):41-45.
[6] CHEN R Y;YEUN W Y D .Review of the high-temperature oxidation of iron and carbon steels in air or oxygen[J].Oxidation of Metals,2003,59(5/6):433-468.
[7] 钢铁研究总院结构材料研究所;先进钢铁材料技术国家工程研究中心;中国金属学会特殊钢分会.钢的微观组织图像精选集[M].北京:冶金工业出版社,2009
[8] 邢光熹;朱建国.土壤微量元素和稀土元素化学[M].北京:科学出版社,2003
[9] 刘慧丛,邢阳,李卫平,朱立群.湿热贮存环境下电子器件表面镀层的腐蚀研究[J].材料工程,2010(02):58-63.