欢迎登录材料期刊网

材料期刊网

高级检索

本文实验研究了低质量流速(500~800 kg·m~(-2)·s~(-1))下的立式螺旋管临界热负荷,对沸腾传热恶化壁温特性和螺旋管临界热负荷影响因素进行分析.并同前人工作汇总,以流量,压力和临界干度为参数,建立了基于局部条件假设的立式螺旋管临界热负荷查询表(Look-Up-Table),共272个点.压力范围6.5~21 MPa,质量流速范围500~1800 kg·m~(-2)·s~(-1).

In this paper,we firstly experimentally investigate the deterioration of heat transfer in a helically coiled tubes at low mass velocity(500~800 kg·m~(-2)·s~(-1)).We analyze the factors affecting of the deterioration of heat transfer coefficient correlations and the deterioration of heat transfer in helically coiled tubes.Based on previous work,a new look-up-table for critical heat flux has been set up,using mass flow rate,pressure and critical steam quality as parameters and based on the hypothesis of local conditions.In the range of mass flow rate of 500~1800 kg·m~(-2)·s~(-1) and pressure of 6.5~21 MPa.the LUT has 272 points.

参考文献

[1] D C Groenevel LKHL;P L Kirillov .The 1995 Look-UP Table for Critical Heat Flux in Tubes[J].Nuclear Engineer-ing and Design,1996,163:1-23.
[2] 甄飞强 .立式螺旋管内水/蒸汽两相流动沸腾传热及其恶化研究[D].西安:西安交通大学,2007.
[3] 毕勤成;陈听宽;田永生 等.螺旋管内高压汽水两相传热恶化规律研究[J].西安交通大学学报,1996,30
[4] 周芳德 .螺旋管内汽(气)液两相流动和传热特性研究[D].西安:西安交通大学,1985.
[5] Styrikovich M A PVS;Reshetov V V .Experimental In-vestigation of the Critical Heat Flux and Post-Dryout Temperature Regime of Helical Coils[J].International Journal of Heat and Mass Transfer,1984,27:1245-1250.
[6] V I Breus Ⅱ .Burnout in Helical Coils at High Pressures[J].Thermal Engng,1983,30(10):592-596.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%