为提高医用钛合金Ti-3Zr-2Sn-3Mo-25Nb的抗凝血性能,首先通过溶胶-凝胶法在其表面制备一层TiO2薄膜,再将该TiO2薄膜活化处理,最后通过静电自组装法将牛血清白蛋白固定在TiO2薄膜表面形成抗凝血涂层。利用X射线衍射仪(XRD)、扫描电子显微镜(SEM)和接触角测试仪研究了该抗凝血涂层的相结构、表面微观形貌和亲水性特征,并通过动态凝血时间法和血小板黏附实验对比研究了白蛋白修饰前后Ti-3Zr-2Sn-3Mo-25Nb合金的抗凝血性能。结果表明,经白蛋白表面修饰处理后, Ti-3Zr-2Sn-3Mo-25Nb合金的抗凝血性能得到了明显的改善。
In order to improve the anticoagulation and haemocompatibility of Ti-3Zr-2Sn-3Mo-25Nb alloy, a layer of TiO2 film was prepared by sol-gel method on the surface , then the coated samples were treated by hydroxyl solution and amination solution in order to introduce the OH -and NH2 -active groups , the albumin was linked on the surface of TiO2 film through the active amidine group by the electrostatic self-assembly multilayer method finally .The phase iden-tification and surface characteristics of the coatings were successively performed and tested by XRD and SEM .The he-mocompatibility of the Ti-3Zr-2Sn-3Mo-25Nb alloy in vitro with and without albumin-immobilization were evaluated by clotting time measurement test and platelet adhesion test , and the results showed that the anticoagulation and haemo-compatibility of the Ti-3Zr-2Sn-3Mo-25Nb alloy could be remarkably improved by surface modification via albumin-im-mobilization .
参考文献
[1] | Pradier CM.;Costa D.;Rubio C.;Compere C.;Marcus P. .Role of salts on BSA adsorption on stainless steel in aqueous solutions. I. FT-IRRAS and XPS characterization[J].Surface and Interface Analysis: SIA: An International Journal Devoted to the Development and Application of Techniques for the Analysis of Surfaces, Interfaces and Thin Films,2002(1):50-54. |
[2] | Weng Y J;Qi F;Huang N et al.Photochemical immobi-lization of bovine serum albumin on Ti-O and evaluations in vitro and in vivo[J].Applied Surface Science,2008,255(02):489-493. |
[3] | Brynda E;Houska M;Jirouskova M;Dyr JE .Albumin and heparin multilayer coatings for blood-contacting medical devices.[J].Journal of biomedical materials research, Part B. Applied biomaterials,2000(2):249-257. |
[4] | Kowalczyńska, H.M.;Nowak-Wyrzykowska, M.;Szczepankiewicz, A.A.;Dobkowski, J.;Dyda, M.;Kamiński, J.;Ko?os, R. .Albumin adsorption on unmodified and sulfonated polystyrene surfaces, in relation to cell-substratum adhesion[J].Colloids and Surfaces, B. Biointerfaces,2011(2):536-544. |
[5] | Chrzanowski,W;Neel,EA;Armitage,DA;Knowles,JC .Effect of surface treatment on the bioactivity of nickel-titanium.[J].Acta Biomaterialia,2008(6):1969-1984. |
[6] | Claudia Sperling;Milan Houska;Eduard Brynda .In vitro hemocompatibility of albumin-heparin multilayer coatings on polyethersulfone prepared by the layer-by-layer technique[J].Journal of biomedical materials research, Part A,2006(4):681-689. |
[7] | 余森,于振涛,牛金龙,韩建业,刘春潮.医用Ti3Zr2Sn3Mo25Nb钛合金表面自组装活性抗凝血复合涂层的构建及其血液相容性[J].金属热处理,2012(09):16-20. |
[8] | Weng, YJ;Hou, RX;Li, GC;Wang, J;Huang, N;Liu, HQ .Immobilization of bovine serum albumin on TiO2 film via chemisorption of H3PO4 interface and effects on platelets adhesion[J].Applied Surface Science,2008(9):2712-2719. |
[9] | Zhentao Yu;Gui Wang;Xiqun Ma.Development of Biomedical Near beta Titanium Alloys[J].Materials Science Forum,2009:303-306. |
[10] | 张明华,于振涛,周廉,张殿忠.β型钛合金材料的生物相容性评价[J].稀有金属材料与工程,2007(10):1815-1819. |
[11] | Milan Houska;Eduard Brynda;Andrey Solovyev .Hemocompatible albumin-heparin coatings prepared by the layer-by-layer technique. The effect of layer ordering on thrombin inhibition and platelet adhesion[J].Journal of biomedical materials research, Part A,2008(3):769-778. |
[12] | Wen T.;Shen JY.;Zhou ZS.;Gao JP. .Preparation and characterization of TiO2 thin films by the sol-gel process[J].Journal of Materials Science,2001(24):5923-5926. |
[13] | Michael Gratzer .Sol-Gel Processed TiO_2 Films for Photovoltaic Applications[J].Journal of Sol-Gel Science and Technology,2001(1/2):7-13. |
[14] | Xuanyong Liu;Paul K. Chu;Chuanxian Ding .Surface modification of titanium, titanium alloys, and related materials for biomedical applications[J].Materials Science & Engineering, R. Reports: A Review Journal,2004(3/4):49-121. |
[15] | Huang N;Yang P;Leng YX;Chen JY;Sun H;Wang J;Wang GJ;Ding PD;Xi TF;Leng Y .Hemocompatibility of titanium oxide films.[J].Biomaterials,2003(13):2177-2187. |
[16] | Xianghui Wang;Feng Zhang;Changrong Li;Zhihong Zheng;Xi Wang;Xianghuai Liu;Anqing Chen;Zhengbin Jiang .Improvement of blood compatibility of artificial heart valves via titanium oxide film coated on low temperature isotropic carbon[J].Surface & Coatings Technology,2000(0):36-42. |
[17] | Chang Zhang;Jing Jin;Jie Zhao;Wei Jiang;Jinghua Yin.Functionalized polypropylene non-woven fabric membrane with bovine serum albumin and its hemocompatibility enhancement[J].Colloids and Surfaces, B. Biointerfaces,2013:45-52. |
[18] | Khan W;Kapoor M;Kumar N .Covalent attachment of proteins to functionalized polypyrrole-coated metallic surfaces for improved biocompatibility.[J].Acta biomaterialia,2007(4):541-549. |
[19] | Jeyachandran, Y.L.;Mielczarski, J.A.;Mielczarski, E.;Rai, B. .Efficiency of blocking of non-specific interaction of different proteins by BSA adsorbed on hydrophobic and hydrophilic surfaces[J].Journal of Colloid and Interface Science,2010(1):136-142. |
[20] | Norde W.;Giacomelli CE. .BSA structural changes during homomolecular exchange between the adsorbedand the dissolved states[J].Journal of Biotechnology,2000(3):259-268. |
- 下载量()
- 访问量()
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%