讨论了阴极电芬顿体系中电极材料的选择标准,并通过比较选择以钛涂钌铱电极、活性碳纤维电极作为阳极、阴极材料。利用自制的电芬顿反应器,对影响体系处理印染废水效果的各相关因素进行研究。结果表明:阴极电芬顿法处理印染废水效果良好,最佳反应条件:pH值为3,FeSO4投加量为150 mg/L,曝气量为0.1 m3/h,电压为9 V,反应时间为40 min,此时COD的去除率最高,可达到73.5%。
The selection criteria of electrode material in EF-Fenton system was discussed,and by comparing the performance, titanium coated ruthenium iridium electrode was selected as the anode material,ACF electrode as the cathode material. A self-made Electro-Fenton reactor was used to treat printing wastewater,the effects of various factors on the treatment of printing wastewater were experimentally analyzed. The results show that the EF-Fenton system is effective in the treatment of printing wastewater,and the optimal reaction conditions are as follows:reaction pH value of 3,FeSO4 dosage of 150 mg/L,aeration capacity of 0.1 m3/h,voltage of 9 V,time of 40 min. The maximum removal rate of COD reaches 73.5%.
参考文献
[1] | 张斌,刘井军,车玉泉.三维电极法处理印染废水的实验研究[J].吉林化工学院学报,2005(04):19-21. |
[2] | 钟理,陈建军.高级氧化处理有机污水技术进展[J].工业水处理,2002(01):1-5. |
[3] | 解清杰,马涛,王琳玲,陆晓华.六氯苯污染沉积物的电Fenton法处理[J].华中科技大学学报(自然科学版),2005(03):122-124. |
[4] | 杜鹃山,车迪,许彦平,辜文强,杨世东.电芬顿处理亚甲基蓝类染料废水研究[J].黑龙江电力,2010(01):9-12. |
[5] | Aimin Wang;Jiuhui Qu;Jia Ru .Mineralization of an azo dye Acid Red 14 by electro-Fenton's reagent using an activated carbon fiber cathode[J].Dyes and Pigments,2005(3):227-233. |
[6] | Marco Panizza;Giacomo Cerisola .Removal of organic pollutants from industrial wastewater by electrogenerated fenton's Reagent[J].Water research: A journal of the international water association,2001(16):3987-3992. |