Two different types of experimental techniques to perform non-isothermal, unicxial and biaxial fatigue testa were described. A new miniaturised electrothermalmechanical test rig was presented and discussed. It enables testing of small specimens under complex thermomechanical loading conditions. In order to cope with the simulation of well defined biaxial proportional and non-proportional loadings with in-phase and out-of-phase superposition of thermal loads a cruciform biaxial fatigue testing machine has been developed. Special design features of both machines, and the specimens tested, as well as typical test results were discussed.
参考文献
[1] | B Roebuckand;M G Gee .[J].Materials Science and Engineering,1996,A209:358. |
[2] | B.Roebuck;M.G. Gee;J.D. Lord;L.N. McCartney .[J].Materials Science and Technology,1998,14:1001. |
[3] | M W Brown;K.J;K.J.Miller;M.W.Brown .Miller, Multiaxial Fatigue, ASTM STP 853[Z].American Society for Testing and Materials, Philadelphia,1985. |
[4] | A Scholz;C.Berger;A.Samir;R.Bardenheier,eds.H.Frenz and A.Wehrstedt .Kennwertermittlung fur Die Praxis- Werkstoffprufung2002[Z].DVM, Berlin,2002. |
[5] | H Masumotoand;M. Tanaka .Ultra High Temperature Mechanical Testing[Z].Woodhead, Cambridge,1995. |
[6] | R D Lohr;eds. K.T. Rie;P.D.Portella .Low Cycle Fatigue and Elasto-Plastic Behaviour of Materials[Z].Elsevier, Oxford,1998. |
[7] | J McAllister;eds. C.R.Burrows;K.A. Edge .Innovations in Fluid Power-Tth Bath International Fluid Power Workshop[Z].Wiley, Chichester,1994. |
上一张