采用A/O-MBR脱氮除磷工艺对生活污水进行小试试验,通过改变回流策略来强化营养物的去除效果.试验结果表明,间歇回流的运行方式并没有对系统的硝化效果产生影响,全程硝化率达到了99.4%;与连续回流的运行模式相比,TP的去除率明显提高,由57.98%上升到81.5%,出水由2.13 mg/L降到了0.98 mg/L;TN的去除率由于在缺氧池的停留时间变短而有所下降,由77.4%下降至66.3%,出水由10.9 mg/L上升至15.8 mg/L;有机污染的去除率受回流模式的影响较小,去除率稳定在91.9%左右.

参考文献

[1] Buisson H.;Praderie M.;Paillard H.;Cote P. .The use of immersed membranes for upgrading wastewater treatment plants[J].Water Science and Technology,1998(9):89-95.
[2] Qin, JJ;Oo, MH;Tao, GH;Kekre, KA;Hashimoto, T .Pilot study of a submerged membrane bioreactor for water reclamation[J].Water Science and Technology,2009(12):3269-3274.
[3] Chang In-Soung;Pierre Le Clech;Bruce Jefferson et al.Membrane fouling in membrane bioreactors or wastewater treatment[J].Journal of Environmental Engineering,2002,128(11):1018-1029.
[4] Tae-Hyun Bae;Sung-Soo Han;Tae-Moon Tak .Membrane sequencing batch reactor system for the treatment of dairy industry wastewater[J].Process biochemistry,2003(2):221-231.
[5] Li-Mei Yuan;Chuan-Yi Zhang;Yan-Qiu Zhang .Biological nutrient removal using an alternating of anoxic and anaerobic membrane bioreactor(AAAM)process[J].Desalination: The International Journal on the Science and Technology of Desalting and Water Purification,2008(1/3):566-575.
[6] Ahn Kyu-Hong;Song Kyung-Guen;Cho Eulsaeng et al.Ehanced biological phosphorus and nitrogen removal using a sequencing anoxic/anaerobic membrane bioreactor (SAM) process[J].Desalination,2003,157:345-352.
[7] Wang, YL;Yu, SL;Shi, WX;Bao, RL;Zhao, Q;Zuo, XT .Comparative performance between intermittently cyclic activated sludge-membrane bioreactor and anoxic/aerobic-membrane bioreactor[J].Bioresource Technology: Biomass, Bioenergy, Biowastes, Conversion Technologies, Biotransformations, Production Technologies,2009(17):3877-3881.
上一张 下一张