欢迎登录材料期刊网

材料期刊网

高级检索

介绍了TDLAS技术用于燃烧流场诊断的基本原理,比较了直接吸收法与二次谐波法两种测量方法的优缺点,并对TDLAS技术路径积分测量特性进行了分析.基于单台二极管激光器分别建立了两种方法的TDLAS测量系统,直接吸收法测量重复频率为10 kHz,获得了瞬态高温超声速流场温度随时间演化结果;二次谐波法测量重复频率为250 Hz,实现了超燃冲压模拟燃烧室温度的在线测量.对于标定燃烧炉甲烷/空气预混火焰,测量系统在1750 K时温度A类标准不确定度优于0.7%.

参考文献

[1] 刘晶儒,胡志云,张振荣,关小伟,王晟,陶波,叶景峰,张立荣,黄梅生,赵新艳,叶锡生.激光光谱技术在燃烧流场诊断中的应用[J].光学精密工程,2011(02):284-296.
[2] V.L. Kasyutich;P.A. Martin .Towards a two-dimensional concentration and temperature laser absorption tomography sensor system[J].Applied physics, B. Lasers and optics,2011(1):149-162.
[3] Daun, KJ .Infrared species limited data tomography through Tikhonov reconstruction[J].Journal of Quantitative Spectroscopy & Radiative Transfer,2010(1):105-115.
[4] Ruxton, K.;Chakraborty, A.L.;Johnstone, W.;Lengden, M.;Stewart, G.;Duffin, K. .Tunable diode laser spectroscopy with wavelength modulation: Elimination of residual amplitude modulation in a phasor decomposition approach[J].Sensors and Actuators, B. Chemical,2010(1):367-375.
[5] Li Li;Norhana Arsad;George Stewart;Graham Thursby;Brian Culshaw;Yiding Wang .Absorption line profile recovery based on residual amplitude modulation and first harmonic integration methods in photoacoustic gas sensing[J].Optics Communications: A Journal Devoted to the Rapid Publication of Short Contributions in the Field of Optics and Interaction of Light with Matter,2011(1):312-316.
[6] 陶波,叶景峰,赵新艳,张立荣,胡志云,叶锡生.基于激光吸收光谱技术测量瞬态超声速流场温度[J].中国激光,2011(12):217-220.