对仪征化纤化工厂PTA装置中反应器第一冷凝器E-112 壳体腐蚀状况进行了分析.结果表明,高温高压冷凝液的冲刷是造成E-112壳体腐蚀穿孔的 主要原因,并提出相应防护对策.
The corrosion of the first condenser of the PTA reac tor in Yizheng chemical fibre factory has been investigated.The erosion of high temperature high pressure cooling liquid is the main reason for the perforation of the shell of the first condenser E-112.