准确测定化学镀铜液中还原剂乙醛酸含量至关重要.利用醛基与盐酸羟胺加成生成肟的特征反应,采用紫外分光光度法测定碱性化学镀铜溶液中乙醛酸的含量,研究了化学镀铜溶液中各组分、副产物及测定条件(pH值、温度、放置时间、盐酸羟胺用量)对测定结果的影响.结果表明:测试方法及最优条件为取镀液0.5 mL于50 mL比色管中,加入2 g/L盐酸羟胺3 mL,调整pH值至4,于50℃水浴中加热20 min,冷却后定容,以稀释100倍、pH值与待测液相同、不合还原剂的化学镀铜基础液为参比,入射波长为230 nm,室温下2h内测定吸光度;当镀铜溶液稀释液中乙醛酸浓度为0.025~ 0.060 g/L时,其浓度与吸光度呈良好的线性关系,线性回归方程为y=14.26x +0.020 4,线性相关系数r=0.998 2(n=5);测量的平均回收率达99.2%,平均标准差为0.135%.
参考文献
[1] | Bosch Ojeda, C.;Sanchez Rojas, F..Recent applications in derivative ultraviolet/visible absorption spectrophotometry: 2009-2011. A review[J].Microchemical Journal: Devoted to the Application of Microtechniques in all Branches of Science,2013:1-16. |
[2] | Ben Salah M;Abderraba M;Tarhouni MR .Effects of ultraviolet radiation on the kinetics of in vitro percutaneous absorption of lavender oil.[J].International Journal of Pharmaceutics,2009(1/2):33-38. |
[3] | Zhu,D.;Qian,F.;Wu,Y.;Jones,D.S.;Rowe,C.;Narum,D.L.;Duffy,P.;Miller,L.H.;Saul,A. .Determination of protein concentration for protein-protein conjugates using ultraviolet absorption[J].Journal of Immunological Methods,2013(1/2):317-321. |
[4] | ZhaoYQ;LiYC;ZhenY.A Novel Monitoring System for COD Using Optical Ultraviolet Absorption Method[J].Procedia Environmental Sciences,2011(10):2348-2353. |
[5] | 高艳君,李萍,杨利君,王齐明,薛俊鹏,吴大诚,李瑞霞.青蒿素与氢氧化钠反应的动态紫外吸收光谱[J].光谱学与光谱分析,2009(03):786-788. |
[6] | 张素斌,陈锡均.硫酸铜-酒石酸钾钠-头孢克洛体系分光光度法测定头孢克洛[J].化学分析计量,2007(06):54-56. |
[7] | 王玉萍,彭盘英,周耀明.紫外吸光光度法同时测定乙醛酸和乙二醛[J].理化检验-化学分册,2005(03):199-202. |