本文报告了一种可以用于对流化床内固体浓度分布测量的电容层析成象技术。应用这一技术的测量结果,与目前常用的压差法测量结果进行了对比。对在鼓泡流化床的测量结果,二者吻合较好,偏差在8.5%以内;随着流化速度增加,二种测量结果的差距逐渐增加,偏差最大值产生在腾涌流化状态。本文分析了造成偏差的原因,并对二种测量方法的特性进行了讨论

An investigation into the solids concentration distribution in a fluidised bedwas conducted. Measurements were taken using electrical capacitance tomographicand a pressure difference method. In the bubbling fluidization regime, the concentrationmeasured using the pressure difference method showed reasonable agreement withthe tomographic technique, with differences below about 8.5%. The discrepancybetween the two methods increased as fluidisation became increasinglyturbulent with a maximum corresponding to slugging fluidisation. Thecharacteristics of the two measuring methods were discussed and reasons forthese differences are suggested

参考文献

[1] J Nieuwland .Measurements of Solids Concentration and AxialSolids Velocity in Gas-Solid Two-Phase Flows[J].Powder Technology,1996,87:127-139.
[2] Bai E Shibuya;N Nakagawa et al.Characterization of GasFluidization Regimes Using Pressure Fluctuations[J].Powder Technology,1996,87:105-111.
[3] Wang T Dyakowsk.Imaging of Fluidized Bed Flow Patterns UsingElectrical Capacitance Tomography[J].IChemE Event,1997
[4] Wang,T Dyakowski;M S Beck.An Application of ElectricalCapacitance Tomography to Measure Gas-Solid Motion in Fluidized Bed[A].Heat-transfer,Houston,1996:155-160.
[5] S Beck;T Dyakowski;S Wang .Measurement of Fluidization Dynamicsin a Fluidized Bed Using Capacitance Tomography[R].IFPRI International FineParticle Research Institute, annual report,1996.
[6] Amos .An Investigation into Circulating Fluidised Bed[D].University of Bradford,1994.
[7] Geldart,J M Hurt;P Wadia.Slugging in Beds of Large Particles[A].Application to Coal ConversionProcessing,1978:60-66.