简单阐述了RFQ冷却聚束器对缓冲气体的要求,从理论和实验两方面详细研究了RFQ1L系统的压升率.研究表明,RFQ1L系统压升率的主要来源是真空室内材料表面的出气,整个系统的压升率实测为(0.04±0.02) Pa/h.
参考文献
[1] | Huang W X,Wang Y,Xu H S,et al.HEP & NP,2004,28:90 (in Chinese).(黄文学,王玥,徐瑚珊等.高能物理与核物理,2004,28:90.) |
[2] | Huang W X,Wang Y,Xu H S,et al.HEP & NP,2005,29:802 (in Chinese).(黄文学,王玥,徐瑚珊等.高能物理与核物理,2005,29:802.) |
[3] | Huang Wenxue,Wang Yue,Xu Hushan,et al.Nuclear Physics Review,2005,22:81 (in Chinese).(黄文学,王玥,徐瑚珊等.原子核物理评论,2005,22:81.) |
[4] | Huang Wenxue,Wang Yue,Xu Hushan,et al.Nuclear Physics Review,2005,22:254 (in Chinese).(黄文学,王玥,徐瑚珊等.原子核物理评论,2005,22:254.) |
[5] | Huang Wenxue,Wang Yue,Zhu Zhichao,et al.Nuclear Physics Review,2006,23:383 (in Chinese).(黄文学,王玥,朱志超等.原子核物理评论,2006,23:383.) |
[6] | Huang W X,Wang Y,Zhu Z C,et al.HEP & NP,2006,30:261 (in Chinese).(黄文学,王玥,朱志超等.高能物理与核物理,2006,30:261.) |
[7] | Da D A.Handbook of Vacuum Design.3rd ed.Beijing:Nation Defense Industry Press,2004,1 331 (in Chinese).(达道安.真空设计手册.第3版.北京:国防工业出版社,2004,1 331.) |
[8] | Yang X T,Meng J,Zhang J H,et al.Vacuum,2004,41:24 (in Chinese).(杨晓天,蒙峻,张军辉等.真空,2004,41:24.) |
上一张