Yingjie HUA
,
Xin LIU
,
Changgong MENG
,
Dazhi YANG
材料科学技术(英文)
The discrete-variational method within the framework of density functional theory was used to investigate the process of O2 adsorption occurring on the surface of NiTi alloy. The calculated results showed that O2 exhibits the adsorption state of Odelta2 (0.36
关键词:
NiTi
,
null
,
null
Jingxiao LIU
,
Jihua CHEN
,
Dazhi YANG
,
Weiqiang WANG
,
Yinong WANG
,
Yingji CAI
材料科学技术(英文)
The biocompatibility of implants is determined by their corrosion resistance and surface characteristics. In this study, the surface composition, morphology and microstructure of TiO2/Ta2O5 films synthesized by ion beam enhanced deposition on NiTi alloy were studied. The scratch test results indicate that the interface adhesive strength of TiO2/Ta2O5 film increases with the increasing Ta content. The electrochemical corrosion measurement shows that the TiO2-36%Ta2O5 film is optimal for improving corrosion resistance of NiTi alloy.
关键词:
Wei WU
,
Xinjie LIU
,
Huimin HAN
,
Dazhi YANG
材料科学技术(英文)
A modified electrolyte (CH3COOH-HClO4-A-B) for electropolishing (EP) of NiTi was presented for improving the corrosion resistance and biocompatibility of the alloy. Using the proposed parameters, a homogeneous and uniform surface was obtained. Atomic force microscopy (AFM) revealed that the surface roughness (Ra) for EP sample (23.21 nm) was close to mechanical polishing (MP) sample (19.36 nm). Analysis by X-ray photoelectron spectroscopy (XPS) showed that Ti/Ni ratio increased from 3.1 for MP sample to 27.6 for EP sample. Measurements using potentiodynamic polarization in Hanks0 solution showed that no pitting occurred for EP sample even though the applied potential increased up to 1500 mV (vs SCE), while the MP sample was broken down at 650 mV. The present study indicates that electropolishing NiTi with this modified electrolyte contributes to the improved biocompatibility of NiTi.
关键词:
NiTi
,
null
,
null
,
null
,
null
Yanjun ZHENG
,
Lishan CU
,
IYan LI
,
Dazhi YANG
材料科学技术(英文)
The reverse martensitic transformation of TiNi shape memory alloy fibers embedded in a pure aluminum matrix was studied in this paper. Results showed that the phase composition of the TiNi alloy fibers prior to prestraining at the room temperature had a significant influence on the differential scanning calorimetry (DSC) results of the composites. By a comparison to the high temperature X-ray diffraction (XRD) results, it was confirmed that the martensite was divided into two groups: the self-accommodating martensite (SAM) and the preferentially oriented martensite (POM). The evolving process of the separation of martensite was discussed.
关键词:
Shape memory alloy
,
null
,
null
,
null
Xiaopeng LIU
,
Wei JIN
,
Mingzhou CAO
,
Dazhi YANG
,
Feixia CHEN
材料科学技术(英文)
Compared with the undeformed TiNi film, the martensite-austenite transformation (M-A) of the deformed one is elevated to a higher temperature on the first heating, but it nearly returns back to the original temperature on the second heating. An incomplete M-A transformation of the deformed TiNi film on the first heating divides the total martensite population into the self-accommodating martensite M2 and the oriented martensite M1. Thus, two transformations corresponding to M1-A and M2-A transition occur on the second heating. However, the forward transformation is not affected by the incomplete thermal cycle.
关键词:
TiNi film
,
null
,
null
,
null
Jingxiao LIU
,
Fei SHI
,
Dazhi YANG
材料科学技术(英文)
In order to improve the corrosion resistance and biocompatibility of NiTi surgical alloy, TiO2 and TiO2-SiO2 thin films were prepared by sol-gel method. The surface characteristics of the film, which include surface composition, microstructure and surface morphology, were studied by X-ray diffraction (XRD), atomic force microscopy (AFM) and X-ray photoelectron spectra (XPS), respectively. A scratching test was used to assess the interface adhesive strength between the film and substrate. The corrosion resistances of NiTi alloy coated with oxide films were studied by anodic polarization curves measurement in biological solution. Additionally, a preliminary study of the in vitro bioactivity of the films was conducted. The results indicated that TiO2 and TiO2-SiO2 (Ti/Si=4:1) films have higher electrochemical corrosion resistance and can be used as protective layers on NiTi alloy. In addition, TiO2-SiO2 composite films have better bioactivity than TiO2 film.
关键词:
TiO2
,
null
,
null
,
null
,
null
Canying CAI
,
Qibin YANG
,
Hongrong LIU
材料科学技术(英文)
Assuming that the wave function , the Schrodinger equation can be written as . Neglecting the last two terms, an analytical expression of electron dynamical diffraction was derived by Qibin YANG et al. In this paper, the analytical expression is modified by further considering the second-order differential term . When the accelerating voltage is not very high, or the sample is not very thin, the reciprocal vector ɡ is large, the modification of the second-order differential is necessary; otherwise it can be neglected.
关键词:
Electron dynamical diffraction
,
null
中国腐蚀与防护学报
N。1Atmospheric Corrosivlty for Steels………………………………………………… .LIANG Caideng HO[I i。-tat(6)Caustic Stress Corrosion Cr。king of Alloy 800 Part 2.The Effect of Thiosul执e……………………………………… KONG De-sheng YANG Wu ZHAO Guo-zheng HUANG De.ltL。ZHANG Yu。。he CHEN She。g-bac(13)SERS slid E16CttOCh6iniC81 Stlldy Of Illhibit1Oli M6ch&tllsth Of ThlollY68 Oil ITOll ID H....
关键词:
颜慧成
,
郭征
,
张孟亭
,
张洪平
钢铁研究学报
引入变量m(冲量密度)和Yang-Mills型规范变换m=u+gradφ,将原始变量的N-S方程转化为规范-不变量形式,用自由质点法处理Voronoi元,对连铸结晶器弯月面处保护渣流动行为进行数学模拟.输出振动周期内的动态流场,然后结合一组试验数据进行计算,计算结果与实际情况相吻合,进而讨论了渣圈对液渣流动行为的影响,为研究结晶器弯月面处保护渣的行为和铸坯振痕的形成提供了一定的依据.
关键词:
连续铸钢
,
保护渣
,
流动行为
,
数学模拟
章明川
,
张楚
,
林郁郁
,
徐旭常
工程热物理学报
根据快速流化床的基本流动特性、A 型噎塞和 C 型噎塞的特征与定义,建立了一个统一,自恰的快速床模型一分相共存模型.模型以 A 型噎塞的修正Yang公式为‘本构方程',合理预报了快速床的最小固体流率Gsm,以及在固体流率不变的条件下降低操作气速时床层由A型噎塞向C型噎塞的连续过渡.模型中的稀相有效气流速度函数幂次n为可调参数,根据 C 型噎塞速度预报的Yousfi and Gau公式,初步确定模型参数n=4.
关键词:
快速流态化
,
噎塞速度
,
A 型噎塞
,
C 型噎塞
,
分相共存模型