Luming LI
,
Songling HUANG
,
Peng ZHENG
,
Keren SHI
材料科学技术(英文)
The magnetic field distribution characteristics of surface cracks with various widths are discussed based on finite element (FEM) results. The crack depth was 0.20 mm, the width range was from 0.02 to 1.00 mm. The results showed that crack width and lift-off (the distance between surface and sensor) will influence signals. Discussed in this paper is the influence of various lift-off parameters on the peak to peak values of the normal component in magnetic flux leakage testing. The effects can be applied to evaluate surface breaking cracks of different widths and depths. An idea is presented to smooth narrow, sharp crack tips using alternating current (AC) field magnetization.
关键词:
Magnetic flux leakage testing (MFL)
,
null
,
null
Songling HUANG
,
Luming LI
,
Haiqing YANG
,
Keren SHI
材料科学技术(英文)
A key issue, which influences the applications of magnetic flux leakage testing, is defect quantification. There have been many research on the relationship between width, depth and magnetic flux leakage of slot defect. However, the length factor is often ignored. The relationship between characteristics of defect leakage field and defect length was investigated. The magnetic flux leakages of a series of plate specimens with the same width, same depth and different length slot defects were tested under the same magnetizing conditions. Testing results show that defect length is an important parameter needed to consider in quantifying defects.
关键词:
Magnetic flux leakage (MFL) testing
,
null
,
null