CHANG Lizhong
,
SHI Xiaofang
,
YANG Haisen
,
LI Zhengbang
钢铁研究学报(英文版)
The effect of frequencies of AC power supply on the quality of the electroslagmelted ingot is studied. The results show that with a decrease in the frequency, electromagnetic force becomes more violent, and the temperature in the slag bath becomes more homogeneous, and therefore, the depth of molten metal pool is decreased; electrochemical reactions occur with the decrease in the frequency, and the atomic oxygen electrolyzed dissolves in the molten metal pool; the nonmetallic inclusions, which are distributed dispersively in the ingot, have an increased content, and their size is approximately in the range of 2-3 μm.
关键词:
electroslag remelting;lowfrequency AC power supply;molten metal pool;oxygen;electrolytic reaction