Mg-6Al-(Sr, Ca)合金的显微组织和蠕变性能

白晶 , 孙扬善 , 薛烽 , 薛山 , 强婧 , 陶卫健 , 刘海峰

金属学报

陶卫健, 刘海峰//金属学报.—2006;42(12).12671273 系统研究了Mg-6Al-2Sr和Mg-6Al-(1-2)Sr-1Ca合金在水冷模铸造和压铸态下的显微组织、力学及蠕变性能. Mg-6Al-2Sr合金的铸态组织由-Mg和沿枝晶界分布呈片状的-Mg+Al4Sr共晶相组成. 在Mg-6Al-2Sr基础上加入少量的Ca, 合金中的Al4Sr被Mg2Ca取代, 且出现了Mg-Al-Sr三元中间相, 合金的抗蠕变性能显著提高. 对蠕变后试样进行的扫描电镜观察表明, Mg-6Al合金中添加Sr和Ca后形成的中间相均具有很高的热稳定性. Mg-6Al-2Sr合金蠕变后的试样中出现了-Mg17Al12相的非连续析出; 而采用Sr和Ca复合合金化的试样显微组织在蠕变后无明显变化, 也未析出相, 因而显著地提高了合金的抗蠕变性能. 与水冷模铸造试样相比, 压铸试样具有更细的显微组织和更高的室温与高温力学性能, 但抗蠕变性能略低.

关键词: Mg-Al-(Sr , strontium , calcium , die cast

Microstructure and properties of Mg-Li alloy with Ca addition

null , null

金属学报(英文版)

Mg-9wt%Li-2wt%Zn alloy was prepared and studied in this article. The addition of Ca to the alloy from 0.1wt% to 1wt% can refine the α-Mg and the best effect of refinement occurs when Ca content is 0.4wt%-0.5wt%. The billets can be rolled to thin sheets at room temperature, from which it is obvious that the addition of Ca improves alloys' formality, while it decreases with the excess addition of Ca. The results also show that the ultimate tensile strength (UTS) and yield strength (YS) of the alloy with 1wt% Ca may rise by 28% and 25%, respectively, however, the elongation decreases. It is clarified that the adsorption of proper Ca on the grain boundaries refines α-Mg and improves the tensile properties, but the presence of excess Ca and stable Ca2Mg6Zn3 phase worsens the elongation.

关键词: calcium , null , null

电感耦合等离子体原子发射光谱法测定高碳除尘灰中11种元素

夏辉 , 王小强 , 何沙白 , 颜蕙园 , 史洁 , 田彩芳

冶金分析 doi:10.13228/j.boyuan.issn1000-7571.009614

实验重点探讨了高含量碳对除尘灰样品中镁、铝、钾、钙、铬、锰、铜、钡、铅、镉、锌等元素测定的影响,并解决了除碳的问题.样品使用马弗炉高温除碳,采用盐酸-硝酸-氢氟酸-高氯酸消解样品灰分,选择了镁、铝、钾、钙、铬、锰、铜、钡、铅、镉、锌等元素的分析谱线和扣背景模式,建立了使用电感耦合等离子体原子发射光谱法(ICP-AES)测定高碳除尘灰中镁、铝、钾、钙、铬、锰、铜、钡、铅、镉、锌等元素的方法.在仪器最佳工作条件下,各元素校准曲线线性相关系数r均大于0.999 5,方法检出限在1.08~26.01 mg/kg之间.方法应用于除尘灰实际样品中镁、铝、钾、钙、铬、锰、铜、钡、铅、镉、锌的测定,结果的相对标准偏差(RSD,n=11)为0.90%~7.1%,目标元素的加标回收率为90%~117%;按照实验方法测定除尘灰中镁、铝、钾、钙、锌,结果与火焰原子吸收光谱法(FAAS)的测定结果相吻合.

关键词: 电感耦合等离子体原子发射光谱法(ICP-AES) , 除尘灰 , 除碳 , , , , , , , , , , ,

电感耦合等离子体原子发射光谱法测定硫酸氧钒中钙镁镍铜铝铁

成勇

冶金分析 doi:10.13228/j.b0yuan.issn1000-7571.009615

采用盐酸溶解样品,使用基体匹配法配制校准曲线消除基体效应的影响,选择Ca317.933 nm、Mg 285.213 nm、Ni 211.647 nm、Cu 324.754 nm、Al 396.152 nm、Fe 238.204nm作为分析线,电感耦合等离子体原子发射光谱法(ICP-AES)测定硫酸氧钒中钙、镁、镍、铜、铝、铁.进行了1.6 mg/mL钒离子和3.0 mg/mL硫酸根共存体系中基体效应、光谱干扰和连续背景叠加对待测元素测定的影响试验.结果表明,该质量浓度的硫酸根离子对测定不产生影响,而钒对部分待测元素谱线产生光谱干扰,钒基体效应对待测元素均产生正干扰.采用钒基体匹配和同步背景校正相结合的方式消除钒基体的影响,并且优选出未受光谱干扰的各待测元素分析谱线及其背景校正和检测区域,根据试验结果确定了ICP-AES工作条件.钙、镁、镍、铜、铝、铁的质量分数在0.000 1%~0.10%范围内与发射强度成线性,各元素校准曲线的相关系数均大于0.999,背景等效浓度为-0.000 3%~0.000 4%,方法中各元素的检出限为0.000 1%~0.000 3%(质量分数).按照实验方法测定硫酸氧钒中钙、镁、镍、铜、铝、铁,结果的相对标准偏差(RSD,n=8)为2.6%~14%.实验方法用于测定2个硫酸氧钒样品中钙、镁、镍、铜、铝、铁,结果与电感耦合等离子体质谱法(ICP-MS)的测定结果相吻合.

关键词: 电感耦合等离子体原子发射光谱法 , 硫酸氧钒 , , , , , ,

连续光源火焰原子吸收光谱法测定氧化镍中钴铜锌铁钙镁

朱国忠 , 徐艳燕 , 庞燕

冶金分析 doi:10.13228/j.boyuan.issn1000-7571.010042

采用盐酸溶解样品,选择Co 240.72 nm、Cu 324.75 nm、Zn 213.86 nm、Fe 248.33 nm、Ca 422.67 nm、Mg 202.58 nm作为分析谱线,钴、铜、锌、铁选择3个像素点,钙、镁选择9个像素点,建立了连续光源原子吸收光谱法(CS-AAS)同时测定氧化镍中的钴、铜、锌、铁、钙、镁的方法.实验表明:在100 mL测定液中加入2 mL 200 g/L氯化锶溶液,可消除测定介质(体积分数为2%的盐酸)对待测元素的影响;基体镍对测定的干扰可忽略.在优化的实验条件下,钴、铜、锌、铁、钙、镁的校准曲线相关系数均不低于0.999 0,且其方法检出限在0.002~0.092 μg/mL之间.按照实验方法对氧化镍样品中钴、铜、锌、铁、钙、镁分别平行测定11次,钙和镁的测定值在0.1%~0.4%之间,其对应的相对标准偏差(RSD)不大于2%;钴、铜、锌、铁的测定值在0.003%~0.04%之间,其对应的相对标准偏差均小于10%.将实验方法应用于电真空镍光谱标准样品(该标样为氧化镍状态)中上述各元素的测定,结果与认定值基本一致.

关键词: 连续光源原子吸收光谱法(CS-AAS) , 氧化镍 , , , , , ,

TENSILE STRENGTH AND CREEP RESISTANCE OF Mg-9Al-1ZnBASED ALLOYS WITH CALCIUM ADDITION

Y.S. Sun , W.M. Zhang , X.G. Min

金属学报(英文版)

Small amount of calcium addition to the Mg-9Al-0. 8Zn-0.2Mn(AZ91) alloy resulted in the obvious influence on mechanical properties. The yield strength of the alloys increased with the increase of Ca addition and maximum strength was obtained from the alloy containing 0.15% of Ca. The creep resistance at the temperatures between 150-200°C was also significantly increased with Ca addition. The creep rate (at 200°C,50MPa) of the alloy with 0. 15% of Ca addition was one order of magnitude lower than that of the base alloy (AZ91). Microstructural observations revealed that the addition of calcium refined the microstructure and enhanced the thermal stability of the β precipitates, which accounted for the improvement of creep resistance at high temperatures.

关键词: tensile strength magnesium alloy , null , null

火焰原子吸收光谱法测定云冈石窟风化岩石中钙铜铁锰

刘月成 , 王尚芝 , 李海 , 杨成全 , 樊俊莉

冶金分析 doi:10.3969/j.issn.1000-7571.2010.02.008

采用HF-HNO_3-HClO_4混酸消化样品,HNO_3溶解盐类,火焰原子吸收光谱法直接测定试液中钙、铜、铁、锰的含量.对共存离子的干扰情况进行了考察,发现大量的Si对测定有干扰,在处理样品时通过生成SiF_4除去;磷、铝、钛等元素对钙的化学干扰,通过加入释放剂SrCl_2消除.背景吸收使用氘灯扣除.采用标准曲线法测定,Ca、Cu、Fe、Mn的校准曲线的线性范围分别为0.00~20.00μg/mL、0.00~6.00弘g/mL、0.00~10.00 μg/mL、0.00~6.00μg/mL,检出限分别为0.000 3μg/mL、0.001 3 μg/mL、0.002 6μg/mL、0.006 9 μg/mL.方法用于云冈石窟风化岩石中钙、铜、铁、锰的测定,相对标准偏差分别为2.8%、3.0%、1.4%、2.9%,加标回收率在96%~110%之间.

关键词: 火焰原子吸收光谱法 , , , , , 风化岩石 , 云冈石窟

电感耦合等离子体原子发射光谱法测定氟钽酸钾中钙镁铁硅

伏军胜 , 郝红梅 , 张俊峰

材料开发与应用

采用智能样品消解仪并以硝酸、氢氟酸溶解样品,建立了电感耦合等离子体原子发射光谱仪(ICP-OES)测定氟钽酸钾中钙、镁、铁、硅的分析方法.实验优化了仪器工作条件,选择Ca 396.847 nm、Mg 279.553nm、Fe239.562 nm和Si 251.612 nm谱线作为分析线,采用基体匹配、扣除背景和标准加入法克服了基体效应和光谱干扰.结果表明,各元素的检出限为0.001 3-0.005 9μg/mL,加标回收率在94.4%-106.0%,相对标准偏差RSD≤4.19%,钙、镁、铁测定结果与直流电弧原子发射光谱法测定结果吻合,硅测定结果与甲基绿-硅钼杂多酸分光光度法的一致,具有较好准确度和精密度.

关键词: 电感耦合等离子体原子发射光谱法(ICP-OES) , 标准加入法 , 氟钽酸钾 , , , ,

电感耦合等离子体原子发射光谱法测定硅锰锆孕育剂中铝钙钡锰锆

左良

冶金分析 doi:10.13228/j.boyuan.issn1000-7571.009903

通过硝酸-氢氟酸-盐酸分解试样,高氯酸冒烟驱走硅和氟,最后用盐酸溶解盐类,选择Al 396.152 nm、Ca 315.887 nm、Ba 233.527 nm、Mn 257.610 nm、Zr 339.197 nm作为分析线,电感耦合等离子体原子发射光谱法(ICP-AES)测定硅锰锆孕育剂中铝、钙、钡、锰、锆.通过对试液分取稀释,降低和避免了铁离子共存体系中基体效应和光谱干扰对待测元素测定的影响.铝、钙、钡、锰、锆质量浓度在0.50~4.00μg/mL 时与其发射强度呈线性,校准曲线的线性相关系数均大于0.9999;方法中铝钙、钡、锰、锆的检出限为0.60 ~ 1.1 μg/g.按照实验方法测定硅锰锆孕育剂中铝、钙、钡、锰、锆,结果的相对标准偏差(RSD ,n = 10)为1.6% ~3.0% ,并与其他方法测定结果基本一致.

关键词: 电感耦合等离子体原子发射光谱法(ICP-AES) , 硅锰锆孕育剂 , , , , ,

Versatic 10萃取体系和由Versatic 10和Cyanex 301组成的复配体系萃取分离硫酸盐溶液中镍钴和钙镁

管青军 , 孙伟 , 周桂英 , 刘佳鹏 , 殷志刚

中国有色金属学报(英文版) doi:10.1016/S1003-6326(16)64178-X

考察萃取剂Versatic 10以及它和Cyanex 301组成的复配萃取体系从含有镁钙离子的硫酸盐溶液中萃取分离镍钴离子的萃取和反萃特征。Versatic 10萃取分离镍钴和钙镁的最佳条件为初始pH值为2.5、油水体积比O/A为1/3、皂化率为60%。Versatic 10的负载有机相用2 mol/L的硫酸溶液以O/A为1/1进行反萃。复配萃取体系中Versatic 10和Cyanex 301的最佳体积比为7/3,复配体系能有效降低镍钴和钙镁萃取分离的平衡pH值至3.50,当O/A为1/2时,2 mol/L的硫酸溶液可以对负载有机相进行有效反萃。Versatic 10与金属离子进行萃取的反应机理为离子交换,而Cyanex 301与金属离子之间不仅有离子交换还有强烈的配位效应,这种配位效应在复配体系与金属离子萃取过程中被大大削弱。

关键词: 溶剂萃取 , Verrsatic 10 , Cyanex 301 , , , ,