LIN Junshan YAN Wenbin TU Mingjing Xi'an Jiaotong University
,
Xi'an
,
China
金属学报(英文版)
The method to detect the crack initiation point of Charpy pre-cracked specimen under dy- namie loading was studied using strain gauge.The load-time curve and nominal strain-time curve at the crack tip for impact testing specinens may be shnultaneously measured by twin-channel oscilloscope with high speed sampling and diskette storing.Based on the dynam- ic finite element simulation of impact response of Charpy specimen,the measuring method of dynamic fracture toughness was analysed and some problems in previous dynamic fracture toughness measurement were discussed.
关键词: